广州伟伯科技有限公司
您的位置:首页 > 产品中心 > Ceriodaphnia dubia, 48-hr Acute, non-renewal, 25℃, MHSF
产品搜索:

Ceriodaphnia dubia, 48-hr Acute, non-renewal, 25℃, MHSF

产品编号:3424323
规格:Proficiency Testing Material
包装规格:1 EA
产品类别:进口试剂
品牌:Supelco
优惠价:立即咨询
产品价格
产品编号包装单位单价(元)国内现货国外库存询价单
34243231 EA1430
基本信息
NACRES
NA.24
General description【一般描述】
This Whole Effluent Toxicity (WET) proficiency testing sample is produced in accordance with ISO/IEC 17043:2010. This product is produced according to TNI requirements. However, please note, this sample may include non-TNI analytes as well.

In Acute WET tests, invertebrate Ceriodaphnia dubia is employed as a test organism to determine its mortality upon exposure to the effluent for a short duration (48 h). This helps arrive at the lethally toxic concentrations of the effluent.

Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs. Our PT program is designed to meet the quality assurance requirements in compliance with Discharge Monitoring Report - Quality Assurance Program (DMR-QA), thereby ensuring the analytical competence of your laboratory.

Analyte/s: Values of analytes vary lot to lot.

All information regarding the use of Ceriodaphnia dubia, 48-hr Acute, non-renewal, 25 ℃, MHSF proficiency testing standard can be found in the reporting packet which will be available to download at PT Portal.
Application【应用】
Ceriodaphnia dubia, 48-hr Acute, non-renewal, 25 ℃, MHSF proficiency testing material is designed for use in Acute Whole Effluent Toxicity (WET) proficiency testing.

Have any questions? Explore our FAQs.
For more information on this product, please contact our PT Service Team.
Features and Benefits【特点和优势】
We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.

Our proficiency testing (PT) program is a benchmark to:

  • provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
  • provide a comparison of performance with that of other laboratories, nationally and internationally
  • test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
  • provide an independent evaluation of laboratory performance
  • demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

Preparation Note【制备说明】
Description

  • The effluent is provided as a concentrate for dilution in moderately hard synthetic freshwater (MHSF).
  • This concentrate is an EPA-specified toxicant in reagent-grade DI water.
  • Enough material has been provided to run the method at least twice. If you require more toxicant please contact ptservice@milliporesigma.com.
  • Do not deviate from the supplied instructions or EPA Method 2002.0. Contact ptservice@milliporesigma.com before running the test if you see the need to deviate from the test conditions. Deviations may affect your final evaluation.


Preparation Instructions
  • To prepare 1 L of effluent, add 900mL of MHSF to a volumetric flask. Preparation instructions for MHSF can be found in the EPA document EPA-821-R-02-012, page 32.
  • Transfer the entire contents of one ampule to the flask. Rinse the ampule with MHSF and transfer to the volumetric flask. Bring flask to 1 L volume with MHSF.
  • This represents 1 L of effluent water for the test.
  • The effluent prepared according to these instructions represents the sample ready for testing, 100% effluent. This 100 % effluent is split into two 0.5 L aliquots. The first aliquot is your 100% effluent for testing. The second aliquot is diluted with 0.5 L MHSF and mixed. This becomes your 50% effluent sample. Continue diluting half of each sample with the same volume of MHSF to make your 25%, 12.5% and 6.25% effluent dilutions, which represent the five test dilutions.


Required Test Condition
  • Test Type: Static non-renewal
  • Test duration: 48 h
  • Temperature: 25 ºC ±1 ºC. The test must not deviate by more than 3 ºC during the test.
  • Dilution water: Moderately hard synthetic water


Test Conditions
  • Light quality: Ambient laboratory illumination (recommended)
  • Light intensity: 10-20 μE/m2/s (50-100 ft-c) (ambient laboratory levels) (recommended),
  • Photoperiod: 16 h light, 8 h darkness (recommended)
  • Test chamber size: 30 mL (recommended minimum)
  • Test solution volume: 15 mL (recommended minimum),Age of test organisms: Less than 24-h old (required)
  • No. organisms per test chamber: 5 (required minimum)
  • No. replicate chambers per concentration: 4 (required minimum)
  • No. of organisms per concentration: 20 (required minimum)
  • Feeding regime: Feed YCT and Selenastrum while holding prior to the test: newly released young should have food available a minimum of 2 h prior to use in a test.
  • Test chamber cleaning: Cleaning not required.
  • Test solution aeration: None
  • Test concentrations: 5 and a control (required minimum)
  • Dilution series: greater than or equal to 0.5 dilutions series (recommended)
  • Endpoint: Mortality (required)
  • Sample holding requirements: Composite sample within 36 h of effluent preparation (required)
  • Test acceptability criterion: 90% or greater survival in controls
Other Notes【其他说明】
Are you new to Supelco® Proficiency Testing? Be sure to register your account details in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.

When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.

Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.

Whole Effluent Toxicity (WET) tests are designed to predict the impact and toxicity of effluents discharges.

Proficiency Testing Schedule (2021-2022)

DMR-QA (US customers only)
DMR-QA 41 March 19 - July 5, 2021

DMR-QA 42 2022 Dates TBD
Legal Information【法律信息】
Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany
产品性质
Quality Level【质量水平】
100
packaging【包装】
ampule of 4 × 2 mL
concentration【浓度】
in water
application(s)
environmental
format【格式】
matrix material
产品说明
Storage and Stability【储存及稳定性】
Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.
安全信息
Storage Class Code【储存分类代码】
12 - Non Combustible Liquids
WGK
WGK 1
广州伟伯科技有限公司 版权所有 CopyRight ©2006-2024, All Rights Reserved
工信部备案号:粤ICP备08114744号   Page Run Time: 0.0371